Please use this identifier to cite or link to this item: http://inet.vidyasagar.ac.in:8080/jspui/handle/123456789/791
Title: A Study on Effect of Error Field on Toroidal Discharge in Air
Authors: Das, C
Pradhan, S S
Hui, A K
Jana, D C
Keywords: Breakdown threshold
toroidal field
error field
Issue Date: 2009
Publisher: Vidyasagar University , Midnapore , West-Bengal , India
Series/Report no.: Journal of Physical Science;Vol 13 [2009]
Abstract: Breakdown threshold voltage of an electrode less toroidal discharge has been studied using H- type solenoid coil excited by a 13.56 MHz radio frequency power in absence and in presence of a toroidal error field with different pressures, and axial magnetic field for dry air. The breakdown threshold depends on various filling parameters e.g. error field , and magnetic field. Again the floating double probe technique was used to measure the plasma temperature and density in presence of error field using the equivalent resistance method [1,2,3,4,5] for dry air. all measurements were made in a 13.56 mhz inductively coupled radio frequency plasma discharge at different pressures ranging from 0.07 torr to 0.20 torr and magnetic field was varied between 0g to 75g.
Description: 275-283
URI: http://inet.vidyasagar.ac.in:8080/jspui/handle/123456789/791
ISSN: 0972-8791 (Print)
Appears in Collections:Journal of Physical Sciences Vol.13 [2009]

Files in This Item:
File Description SizeFormat 
Art26.pdf339.79 kBAdobe PDFView/Open